Auto ReStart (Advanced Menu)

This setting allows the user to choose between continuous maximum power point (MPP) tracking, or
occasional restarts of the sweeping process. A restart means the controller abandons the existing
maximum power point value it was using and "re-sweeps", or begins gathering new power point data.
(See page 95 for more information on MPP tracking.)
Auto ReStart has three options available:
 Mode 0 – Initial sweep only and then continuous MPP tracking. Auto ReStart is disabled. The FLEXmax will
continously track the maximum power point without starting over.
 Mode 1 – Automatic re-sweep every 90 minutes if controller is in an MPPT mode (MPPT Float, MPPT
Bulk, etc). This will not reset any counters, charging stages, or statistics.
Mode 2 – Automatic re-sweep every 90 minutes if controller is in any charging mode. This will not reset any
counters, charging stages, or statistics.
Auto ReStart Screen
ADVANCED MENU
Auto ReStart
MODE 0
EXIT NEXT
ADVANCED MENU
Auto ReStart
MODE 1
EXIT NEXT
ADVANCED MENU
Auto ReStart
MODE 2
EXIT NEXT
ADVANCED MENU
Auto ReStart
Mode 0
EXIT NEXT
52
To select an Auto ReStart mode:
1.
Navigate to the Auto ReStart screen through the
ADVANCED MENU as instructed in Figure 35.
MODE
2.
Press <MODE> to switch between the three Auto
ReStart modes: MODE 0 (default), MODE1, and
MODE2.
MODE
MODE
To Exit:
Press <NEXT> to advance to the Aux Polarity screen.
MODE
Press <EXIT> once to return to the main menu.
Press <EXIT> twice to return to the status screen.
Figure 45
Auto ReStart
C
900-0009-01-00 Rev

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the OutBack Power FLEXmax Series and is the answer not in the manual?

Questions and answers

This manual is also suitable for:

Outback power flexmax 80Outback power flexmax 60Fm60

Table of Contents