Scale application

The scale applicator (A-9589-0115) is designed for use with RTLC20-S scale.
1
Allow the scale to acclimatise to the installation environment prior to
installation.
2
Mark out the 'START' and 'FINISH' points for the scale on the axis
substrate – ensure that there is room for the optional end covers if required
(see 'RTLC20-S scale installation drawing' on page
3
Thoroughly clean and degrease the substrate using recommended solvents
(see 'Storage and handling' on page
2). Allow the substrate to dry
before applying scale.
4
Mount the scale applicator to the readhead mounting bracket using M2.5
screws. Place the shim supplied with the readhead between the applicator
and substrate to set the nominal height.
NOTE: The scale applicator can be mounted either way round to enable
easiest orientation for scale installation.
Side mounting scale applicator
(A-9589-0115).
5
Move the axis to the scale 'START' position, leaving enough room for the
scale to be inserted through the applicator, as shown below.
6
Begin to remove the backing paper from the scale and insert the scale
into the applicator up to the 'START' point (as shown). Ensure the backing
paper is routed under the splitter screw.
7
Apply finger pressure to the scale at the 'START' point, using a clean
lint-free cloth, to ensure scale end adheres well to the substrate.
VIONiC RTLC20-S installation guide
8
4).

End covers

The end cover kit (A-9585-0035) is designed to be used with RTLC20-S scale to provide protection for
exposed ends.
NOTE: End covers are optional and can be fitted before or after readhead installation.
'START'
M2.5 mounting holes
Slowly and smoothly move the applicator through the entire axis
of travel, ensuring the backing paper is pulled manually from the
scale and does not catch under the applicator.
Direction of scale application
RTLC20-S
Backing tape
Splitter screw
1
Remove the backing tape from the adhesive tape on the back of
the end cover.
2
Align the marker on the edges of the end cover with the end of the
scale and place the end cover over the scale.
NOTE: There will be a gap* between the end of the scale and
the adhesive tape on the end cover.
* gap
9
Remove the applicator and, if necessary,
adhere the remaining scale manually.
Apply firm finger pressure via a clean
lint-free cloth along the length of the
scale after application to ensure complete
adhesion.
10
Clean the scale using Renishaw scale
cleaning wipes (A-9523-4040) or a clean,
dry, lint-free cloth.
'START'
5