Installing the adhesive mounted RELx20/RSLx20 scale
1. Thoroughly clean and degrease the substrate with a lint-free cloth and clean the underside of
the scale using approved solvents (see
2. Mark the area for the epoxy datum clamp on the adhesive tape and cut the tape accordingly.
The epoxy datum clamp fixes the scale rigidly to the substrate at the chosen location.
CAUTION: The metrology of the system may be compromised if the epoxy datum clamp is not used.
30
TONiC™ FS RELM20/ RSLM20 Functional Safety installation guide and safety manual
'Storage and handling'
on page 20)
3. Remove the backing liner from one side of the adhesive tape and stick it to the underside of
the scale.
4. Thoroughly mix and apply the epoxy to the back of the scale and then remove the remaining
backing liner.
Area for RGG-2 epoxy
Original instructions