Modbus/Tcp Mapping; Modbus/Tcp Mapping Table - Advantech EKI-9226G Series User Manual

6xrj45 + 20xsfp port full gigabit l2 managed switch
Table of Contents

Advertisement

4.12

Modbus/TCP Mapping

The data map addresses of Advantech switches shown in the following table start
from Modbus address 30001 for function code 4.
In the given example, the address offset 0x1000 (hex) equals Modbus address
34097, while the address offset 0x1100 (hex) equals Modbus address 34353.
The information given by the Advantech is shown in hex mode.
4.12.1

Modbus/TCP Mapping Table

Catelog
Name
System Info
Vendor ID =
0x'13FE
Unit ID = 0xFF 1 word 16 bits HEX
Product Code 1 word 16 bits HEX
Vendor Name
= "Advantech"
Product Name
= "EKI-xxxx"
Firmware Ver-
sion
EKI-9226G Series User Manual
Data Type
Interpretation
1 word 16 bits HEX
16
32
ASCII
words
chars
16
32
ASCII
words
chars
2
32 bits HEX
words
137
Address
Address
Offset (Hex)
3X
0x0000
30001
Vendor ID = 0x13FE
0x0001
30002
Unit ID = 0xFF
0x0002
30003
Product Code
0x0010
30017
Vendor Name =
"Advantech"
Word 0 Hi byte = 'A'
Word 0 Lo byte = 'd'
Word 1 Hi byte = 'v'
Word 1 Lo byte = 'a'
Word 2 Hi byte = 'n'
Word 2 Lo byte = 't'
Word 3 Hi byte = 'e'
Word 3 Lo byte = 'c'
Word 4 Hi byte = 'h'
Word 4 Lo byte = '\0'
0x0020
30033
Product Name =
"EKI-xxxx"
Word 0 Hi byte = 'E'
Word 0 Lo byte = 'K'
Word 1 Hi byte = 'I'
Word 1 Lo byte = '-'
Word 2 Hi byte = 'x'
Word 2 Lo byte = 'x'
Word 3 Hi byte = 'x'
Word 3 Lo byte = 'x'
Word 4 Hi byte = '\0'
0x020A
30523
Firmware Version
Word 0 Hi byte =
major
Word 0 Lo byte =
minor
Word 1 Hi byte =
release
Word 1 Lo byte =
build
Description

Advertisement

Table of Contents
loading

Table of Contents