Considerations; Grounding The Device - Advantech EKI-9226G Series User Manual

6xrj45 + 20xsfp port full gigabit l2 managed switch
Table of Contents

Advertisement

2.9.2

Considerations

Take into consideration the following guidelines before wiring the device:
The Terminal Block (CN1) is suitable for 12-24 AWG (3.31 - 0.205 mm
value 7 lb-in.
The cross sectional area of the earthing conductors shall be at least 3.31 mm
Calculate the maximum possible current for each power and common wire.
Make sure the power draw is within limits of local electrical code regulations.
For best practices, route wiring for power and devices on separate paths.
Do not bundle together wiring with similar electrical characteristics.
Make sure to separate input and output wiring.
Label all wiring and cabling to the various devices for more effective manage-
ment and servicing.
Note!
Routing communications and power wiring through the same conduit
may cause signal interference. To avoid interference and signal degra-
dation, route power and communications wires through separate con-
duits.
2.9.3

Grounding the Device

Warning! Disconnect all sources of supply before servicing.
Avertissement! Couper toutes les sources d'alimentation avant de faire l'entretien
Warning! If the equipment is used in a manner not specified by the manufacturer,
the protection provided by the equipment may be impaired.
Avertissement! Si l'appareil est utilisé d'une manière non spécifiée par le fabri-
EKI-9226G Series User Manual
et les réparations.
cant, la protection qu'il apporte peut se voir diminuée.
17
2
). Torque
2
.

Advertisement

Table of Contents
loading