Check the flow of lubricant at the con-
sumers
Each lubrication channel at the consum-
ers must be checked as regards clear-
ance.
- Remove the lubrication line (a) and
install a normal lubricating nipple (b).
- Connect the grease gun (c) en-
closed on delivery to the lubricating
nipple (b).
- Operate the grease gun until the lu-
bricant visibly emerges.
- Rectify any faults in the flow of lubri-
cant.
- Reinstall the lubrication lines.
- Check all connections and lines for
leaks.
F 90 6
a
b
c