Fayat Group Dynapac SD2500C Operation & Maintenance Manual page 293

Paver finisher
Table of Contents

Advertisement

Ultrasonic auger limit switches (left
and right) - PLC version
The limit switches control the material
A
flow at the relevant half of the auger
without contact.
The ultrasonic sensor (1) is secured to
the side shield via a bracket (2).
- To adjust, release the clamping lever /
stop screw (3) and adjust the sensor's
angle.
- After adjusting, retighten all mounting
parts properly.
The connection cables (4) are connected to the relevant sockets on the remote con-
A
trol bracket.
The sensors should be adjusted so that 2/3 of the augers are covered with the paving
A
material.
The paving material must be conveyed over the full working width.
A
We recommend adjusting the limit switch positions during material distribution.
A
In vehicles with a PLC control system, the deactivation point is set on the remote con-
A
trol.
1
2
4
3
D 30 29

Hide quick links: