Fayat Group Dynapac SD2500C Operation & Maintenance Manual page 397

Paver finisher
Table of Contents

Advertisement

8.2
Auger limit switches (left and right) -
mounting the conventional version
The ultrasonic sensor (1) is secured to
the side shield via a bracket (2).
- To adjust the sensor angle, loosen the
clamps (3) and swivel the bracket.
- To set the sensor height / the deacti-
vation point, loosen the star handles
(4) and adjust the linkage to the re-
quired length.
- After adjusting, retighten all mounting
parts properly.
The connection cables are connected to
A
the relevant sockets on the remote con-
trol bracket.
The sensors should be adjusted so that
A
2/3 of the augers are covered with the
paving material.
The paving material must be conveyed
A
over the full working width.
We recommend adjusting the limit switch positions during material distribution.
A
2
4
1
3
E 10 47

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dynapac sd2500cs892893