Alternatively, the oil level can be checked and the oil changed at the rear of the gear-
A
box:
- Remove protective cover (A)
- The following are located at the rear of
the gearbox:
- Oil inlet (B)
- Oil level check (C)
- Oil drain (D)
Carry out the oil level check and oil
A
change as per the description above.
m
When draining using the drain (D), a
small residual quantity of oil remains in
the gearbox.
- Max. oil level up to lower edge of oil
check (C).
- Reinstall the protective cover (A) prop-
erly.
F 73 12
B
C
D
A