Item Designation
Auger
122
"MANUAL"
Auger
123
"AUTO"
Auger
124
"Reversing mode"
Brief description
Button with detent switch function and LED feedback:
- The conveying function of the corresponding half of
the auger is switched on continuously with full deliv-
ery capacity, without material control via the
limit switches.
- Switch OFF by pressing the button again
The function is shut off by pressing the EMERGENCY
A
STOP button or restarting the vehicle.
The main function switch locks the conveying function.
A
Button with detent switch function and LED feedback:
- The conveying function of the corresponding half of
the auger is switched on when the drive lever is swiv-
elled out and is continuously controlled via the mate-
rial limit switches.
- Switch OFF by pressing the button again
The function is shut off by pressing the EMERGENCY
A
STOP button or restarting the vehicle.
The main function switch (operating panel) locks the
A
conveying function.
Pushbutton function:
- The auger's conveying direction can be reversed
in order to slightly reverse any paving material which
may be positioned just in front of the auger. This
enables e.g. material losses to be avoided during
transportation.
- Temporally limited reversal is carried out when the
button is pressed continuously.
The auger function must be switched to "AUTO" or
A
"MANUAL" for reversing mode.
In reversing mode, the automatic function is overridden
A
with reduced capacity.
D 11 65