Nortel Media Gateway 3200 User Manual page 242

Hide thumbs Also See for Media Gateway 3200:
Table of Contents

Advertisement

ini File Field Name
User's Manual
Table 12-2: PSTN Parameters
Description
library users. No CAS state machine is
relevant. Users build their state
machine in his application and controls
it via commands of Open channel, send
CAS, and event detection of CAS
changes and digits events.
T1_TRANSPARENT = 4
T1_TRANSPARENT – provides bearer
path termination (T1 system) without
signaling-related functions. Channels 1-
24 mapped to DSP channels. Used for
provisioning SS7 trunk or PRI trunk of
an NFAS group that does not host the D
channel i.e. B-channel span only.
E1_TRANSPARENT_31 = 5
E1_TRANSPARENT_31 – provides
bearer path termination (E1 system)
without signaling-related functions, with
reclaiming timeslot 16. Channels 1-31
mapped to DSP channels. Used for
provisioning SS7 trunk.
Note: If using E1_TRANSPARENT_31,
it is the only protocol type that can be
used on that board (or logical GW).
Note: There are 240 DSP resources per
logical GW. The first 240 channels
requesting a DSP resource have those
resources allocated. Attempt to open
bearer channels beyond that is denied.
E1_TRANSPARENT_30 = 6
E1_TRANSPARENT_30 – provides
bearer path termination (E1 system)
without signaling-related functions.
Channels 1-31, except 16 mapped to
DSP channels. Used for provisioning
SS7 trunk.
Note: Attempts to establish a bearer
path on timeslot 16 are rejected.
E1_MFCR2 = 7
E1_MFCR2 – with Megaco controller
only over Brazilian, Korean and
Mexican R2 variants.
E1_CAS_R2 = 8
E1_CAS_R2 – this protocol type was
changed to E1_CAS. Megaco and
MGCP do not use it. For API Library
242
MG 3200
Host/Manual
Valid
Default Value
Range
Document # LTRT-72704

Advertisement

Table of Contents
loading