Nortel 1000E PRI Installation And Commissioning Manual

Nortel 1000E PRI Installation And Commissioning Manual

Hide thumbs Also See for 1000E PRI:
Table of Contents

Advertisement

Quick Links

Nortel Communication Server 1000
Media Gateway 1000E PRI
Gateway Installation and
Commissioning
Release: 7.0
Document Revision: 04.01
www.nortel.com
NN43041-311
.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 1000E PRI and is the answer not in the manual?

Questions and answers

Summary of Contents for Nortel 1000E PRI

  • Page 1 Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning Release: 7.0 Document Revision: 04.01 www.nortel.com NN43041-311...
  • Page 2 While the information in this document is believed to be accurate and reliable, except as otherwise expressly agreed to in writing NORTEL PROVIDES THIS DOCUMENT "AS IS" WITHOUT WARRANTY OR CONDITION OF ANY KIND, EITHER EXPRESS OR IMPLIED. The information and/or products described in this document are subject to change without notice.
  • Page 3: Table Of Contents

    How to get help Getting help from the Nortel Web site 11 Getting help over the telephone from a Nortel Solutions Center 11 Getting help from a specialist by using an Express Routing Code 12 Getting help through a Nortel distributor or reseller 12...
  • Page 4 Install an E1/T1 expansion daughterboard 57 Install an E1/T1 card 60 Connect the RS-232 cable 61 Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning NN43041-311 04.01 4 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 5 Maintain PRI digital trunk loops 126 Maintain downloadable D-channels 127 PRI startup 128 Maintain DPNSS/DASS and DCHI 132 Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning NN43041-311 04.01 4 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 6 Organization of CLI commands 151 PRI Gateway alarms Media Gateway Controller system alarms, events, and messages Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning NN43041-311 04.01 4 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 7: New In This Release

    New in this Release The following sections detail what’s new in Media Gateway 1000E PRI Gateway Installation and Commissioning (NN43041-311) for the Nortel Communication Server (CS) 1000E system in Release 7.0. Navigation • “Feature changes” (page 7) • “Other changes” (page 7)
  • Page 8 Communication Server 1000 Release 5.5. October 2007 Standard 01.03. This document addresses CRs Q01738360, Q01747312, Q01743445, and Q01741413. Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning NN43041-311 04.01 4 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 9 May 2007 Standard 01.01. This document is issued to support Communication Server 1000 Release 5.0. Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning NN43041-311 04.01 4 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 10 10 New in this Release Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning NN43041-311 04.01 4 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 11: How To Get Help

    How to get help This chapter explains how to get help for Nortel products and services. Getting help from the Nortel Web site The best way to get technical support for Nortel products is from the Nortel Technical Support Web site: www.nortel.com/support This site provides quick access to software, documentation, bulletins, and tools to address issues with Nortel products.
  • Page 12: Getting Help From A Specialist By Using An Express Routing Code

    To access some Nortel Technical Solutions Centers, you can use an Express Routing Code (ERC) to quickly route your call to a specialist in your Nortel product or service. To locate the ERC for your product or service, go to: www.nortel.com/erc...
  • Page 13: Safety Instructions

    • “Handling circuit cards” (page 14) Introduction This section identifies safety issues associated with the installation of the Media Gateway 1000E PRI Gateway. To avoid personal injury and equipment damage, review the safety instructions before handling the equipment. WARNING Failure to follow the safety instructions in this chapter could result in personal injury.
  • Page 14: Power Supply Cables

    Do not stack cards on top of each other unless they are packaged. Wear a properly connected antistatic wrist strap when you work on the equipment. Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning NN43041-311 04.01 4 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 15: Regulatory Information

    EN 61000-3-2 Limits for harmonic current emissions (equipment input current <= 16 A per phase) Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning NN43041-311 04.01 4 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 16 Voluntary Control Council for Interference by for Voluntary Information Technology Equipment (VCCI) Control (see Note 4) Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning NN43041-311 04.01 4 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 17 Note 1c: The user should not make changes or modifications not expressly approved by Nortel. Any such changes could void the user’s authority to operate the equipment.
  • Page 18: Radio And Tv Interference

    • Please use only the connecting cables, power cord, and AC adapters shipped with the equipment or specified by Nortel to be used with the equipment. If you use any other equipment, it may cause "failures, malfunctioning, or fire". •...
  • Page 19: Notice For United States And Canadian Installations

    If trouble is experienced with this equipment, for repair or warranty information please contact: Nortel at 1-800-4Nortel. If the equipment is causing harm to the network, the telephone company can request that you disconnect the equipment until the problem is resolved.
  • Page 20: European Compliance Information

    European compliance information This device complies with the essential requirements and other relevant provisions of R&TTE Directive 1999/5/EC. A copy of the declaration maybe obtained from Nortel GmbH address: Ingolstaedter Strasse 14-18 80807 Munich Germany. Telecom specifications The system meets the following European technical regulations: CTR 4, CTR 12, CTR 13.
  • Page 21: Introduction

    This document provides the information necessary to install and configure a Media Gateway 1000E PRI (Peripheral Rate Interface) Gateway (MG 1000E PRI Gateway). The MG 1000E PRI Gateway is a digital trunk gateway that supports up to eight E1/T1 spans. ATTENTION At this time DTI and JDMI are not supported on the MG1000E PRI Gateway (MGP).
  • Page 22: Applicable Systems

    PRI gateway operation). This package allows you to: • two DCH ports: 0 and 1 on the DDCH DB used with the MG 1000E PRI Gateway • 2x96 DSP DB with the MG 1000E PRI Gateway (defining slot 9 and 10 of MG 1000E as additional DSP resources) •...
  • Page 23: Conventions

    PRI Gateway. Conventions In this document, the CS 1000E Release 7.0 system is referred to generically as the system. The Media Gateway 1000E PRI Gateway is referred to generically as the PRI Gateway. Related information This section lists information sources that relate to this document.
  • Page 24 24 Introduction Online To access Nortel documentation online, click the Technical Documentation link under Support & Training on the Nortel home page: www.nortel.com Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning NN43041-311 04.01 4 June 2010...
  • Page 25: Installation Summary Introduction

    1 Address in existing T-LAN network, must be in the same subnet as the MGC Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning NN43041-311 04.01 4 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 26: Installation Tasks

    DSP daughterboards in a PRI Gateway” (page Configuring an E1/T1 card “Configure an E1/T1 card” (page 83) Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning NN43041-311 04.01 4 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 27: Overview Of The Pri Gateway

    Public Switched Telephone Network (PSTN) for telephones and other IP Phones or other PBXs as shown in. Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning NN43041-311 04.01 4 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 28 E1/T1 ISDN protocols can be configured for each span; each E1/T1 span can be configured with any PRI protocol Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning NN43041-311 04.01 4 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 29: System Configurations

    Gateway replaces the MG 1000E as a PRI/PRI2 digital trunk gateway. Figure 3 PRI Gateway configuration Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning NN43041-311 04.01 4 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 30: Ce-Mux Support

    Table 5 "Shelf slot assignments" (page 31) describes the 16 slot assignments and their mapping. Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning NN43041-311 04.01 4 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 31: Sip Line Service

    (CP DC) cards. Both the SIP Line Gateway and Element Manager reside on the supported Servers. Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning NN43041-311 04.01 4 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 32 For information about SIP Line installation, see Linux Platform Base and Applications Installation and Commissioning (NN43001-315). Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning NN43041-311 04.01 4 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 33: System Components Introduction

    Media Gateway PRI (MGP) package 418 is equipped. Figure 4 "PRI Gateway functional block diagram" (page 34). Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning NN43041-311 04.01 4 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 34: New Components

    DCH Layer 2 (LAP-D) and the UIPE PRI protocols. • a 2u gateway chassis (NTDW72) that includes power supply, backplane and fan Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning NN43041-311 04.01 4 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 35: Redundancy And Field Replaceable Components

    NTDW62AA MGC DSP daughterboard (32 ports) Existing NTBK51AA/NTBK51 DDCH daughterboard Existing NTAK93AB DCHI daughterboard Existing Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning NN43041-311 04.01 4 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 36: E1/T1 Card

    Backplane for the E1/T1 card The E1/T1 card (excluding DCH daughterboards) provides the following hardware features: Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning NN43041-311 04.01 4 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 37 LED display — D-channel TR/RR handshake The E1/T1 card features: Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning NN43041-311 04.01 4 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 38: E1/T1 Card Expansion Daughterboard

    LED indicators on the E1/T1 card • one LED for power • one LED for fans Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning NN43041-311 04.01 4 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 39 "For DDCH/DCHI: Lit when MSDL/DDSL is enabled. For DCHI-SW: Lit when all configured DDSLs (of a pair) are enabled. Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning NN43041-311 04.01 4 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 40: Media Gateway Controller And Dsp Daughterboards

    Fixed switching frequency = 132 kHz • Approvals: UL/ TUV/ CE • EMC approvals: FCC part 15, class A Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning NN43041-311 04.01 4 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 41: D-Channel Daughterboards

    (ports 0 and 1) is physically mapped to spans 1 and 2 of the PRI Gateway (MGC Intelligent Peripheral Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning NN43041-311 04.01 4 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 42 (port 1) is mapped to span 8 of the PRI Gateway (MGC IPE card slot 8 from a system software perspective) Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning NN43041-311 04.01 4 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 43 E1/T1 card) eight span example with package 418 equipped" (page define MSDL or DCHI in the system software as follows: Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning NN43041-311 04.01 4 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 44 1 and define two DCHI on card numbers 3 and 4 using port 1 Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning NN43041-311 04.01 4 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 45 4 using ports 0 and 1 and define four DCHI D-channels on card numbers 5, 6, 7, and 8 using port 1 Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning NN43041-311 04.01 4 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 46: Pri Gateway Span Usage

    DCH interface but is used for B-channels which are served by D-channel interface defined in another span. Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning NN43041-311 04.01 4 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 47 DCHI indicates that the DPNSS/DASS D-channel is using the DCHI daughterboard. • DCHI-SW indicates that the DPNSS/DASS D-channel is using onboard implementation. Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning NN43041-311 04.01 4 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 48: 19-Inch Rack (Customer-Supplied)

    (four on the faceplate and two in the back panel) and one RS-232 connector. Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning NN43041-311 04.01 4 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 49: Pinout For A T1-E1 49

    • up to eight shielded RJ-45 E1/T1 cables All the cables listed here including the MGC cables as well as the connectors listed here are not provided by Nortel and are the responsibility of the distributor to provide: • Power supply cable •...
  • Page 50 CAT5 Ethernet cables compared to E1/T1 cables and can cause problems if used with RJ-48 pinned CSUs and 568 pinned patch panels. Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning NN43041-311 04.01 4 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 51: Rack-Mount And Ground Pri Gateway Components

    .216 - 24 X .500 STL 289A screws (code P097F813) Procedure 1 Rack-mounting a PRI Gateway Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning NN43041-311 04.01 4 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 52: Ground A Pri Gateway

    Place a tag marked DO NOT DISCONNECT on the ground wire at the electrical panel. --End-- Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning NN43041-311 04.01 4 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 53: Install A Media Gateway Controller And Dsp Daughterboard

    Ensure the DSP daughterboard is securely attached to the MGC (using the four supplied screws and standoffs). --End-- Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning NN43041-311 04.01 4 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 54 54 Install a Media Gateway Controller and DSP daughterboard Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning NN43041-311 04.01 4 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 55: Install An E1/T1 Card And Daughterboards Introduction

    This chapter also describes how to remove a daughterboard. See Procedure 5 “Removing NTBK51AA/NTBK51CA and NTAK93AB daughterboards from an E1/T1 card” (page 57). Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning NN43041-311 04.01 4 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 56: Install Ntbk51Aa/Ntbk51Ca And Ntak93Ab Daughterboards

    E1/T1 package. Align the standoffs on the daughterboard with the mounting holes on the E1/T1 card. Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning NN43041-311 04.01 4 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 57: Remove Ntbk51Aa/Ntbk51Ca And Ntak93Ab Daughterboards

    The PRI Gateway supports a base of four spans in the E1/T1 card. However, you can upgrade to eight E1/T1 spans by adding an expansion daughterboard. Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning NN43041-311 04.01 4 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 58 Configure the D-channel for the system software (LD 96 for PRI interfaces or LD 75 for DPNSS/DASS interfaces). --End-- Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning NN43041-311 04.01 4 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 59 J2 and the expansion daughterboard in position on the E1/T1 card. Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning NN43041-311 04.01 4 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 60: Install An E1/T1 Card

    Determine the location of the shelf where you are installing the E1/T1 card. Unpack and inspect the E1/T1 card and DCH daughterboards. Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning NN43041-311 04.01 4 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 61: Connect The Rs-232 Cable

    8 data bits • 1 stop bit • No parity • Flow control is "none" --End-- Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning NN43041-311 04.01 4 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 62 62 Install an E1/T1 card and daughterboards Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning NN43041-311 04.01 4 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 63: Connect Pri Gateway Components

    If the MGC Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning NN43041-311 04.01 4 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 64: Media Gateway Controller Network Connections

    Layer 2 switches, which provides another level of redundancy and no single point of failure with a Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning NN43041-311 04.01 4 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 65 Media Gateway Controller network connections 65 Layer 2 switch. Nortel recommends the use of distributed connections, however, nondistributed is supported if the cost of the additional data networking equipment is an issue. Figure 12 "Single server port configuration: no dual-homing" (page shows the supported configuration for a single server configuration without redundant network configurations.
  • Page 66 ELAN and TLAN network interfaces. Multiple Layer 2 switches are used to ensure there is no single point of failure. Nortel recommends this configuration for highest reliability in a single CPU Call Server configuration.
  • Page 67: Elan And Tlan Subnet Connections

    Procedure 9 “Connecting a Media Gateway Controller to the ELAN subnet” (page 68) to connect an MGC to the ELAN subnet. Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning NN43041-311 04.01 4 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 68: Connect A Media Gateway Controller To The Tlan Subnet

    Connect the RJ-45 shielded Ethernet cable to the CE ports on the MGC. --End-- Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning NN43041-311 04.01 4 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 69: Configure The Media Gateway Controller And Dsp Daughterboards In A Pri Gateway

    • You must configure the MGC itself. The order of these tasks is not critical. However, Nortel recommends that you configure the MGC on the Call Server before you install the MGC. You also configure the DSP daughterboards to support Voice Gateway Channels.
  • Page 70 No input, simply a header for the ELAN/TLAN designators. This header and the ELAN/TLAN prompts only apply to MGC-based IPMGs. --End-- Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning NN43041-311 04.01 4 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 71: Configure The Media Gateway Controller

    SDI cable. A null modem adapter is used to connect to the MGC serial port. Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning NN43041-311 04.01 4 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 72 Here is an example of the configuration of an MGC without any installed DSP daughterboards: Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning NN43041-311 04.01 4 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 73 __________________ You have entered the following parameters for this MG 1000E: ELAN IP : 47.11.216.79 Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning NN43041-311 04.01 4 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 74 Set ELAN to auto negotiate? ([y]/n) : y ELAN security Disabled, change setting? (y/[n]) : y Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning NN43041-311 04.01 4 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 75 TLAN IP, gateway, subnet mask The following MGC configuration changes do not require a reboot to take effect: Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning NN43041-311 04.01 4 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 76: Configure Dsp Daughterboards

    Choose the Superloop Number and Shelf and click Add. The window shown in Figure 16 "Add IPMG" (page 77) appears. Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning NN43041-311 04.01 4 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 77 “CT”, “T2”, and “T”). Click Submit. Click Submit. The window shown in Figure 17 "IPMG MGC configuration" (page 78) appears. Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning NN43041-311 04.01 4 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 78 After configuration of the MGC is complete, the window shown in Figure 18 "Media Gateways" (page 79) appears. Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning NN43041-311 04.01 4 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 79 Save. The window shown in Figure 20 "VGW Channels - IPMG" (page appears. Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning NN43041-311 04.01 4 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 80: Configure A Dsp Daughterboard To Support Voice Gateway Channels Using Ld

    Enter the responses shown in Table 15 "Configure the DSP daughterboard (LD 14) " (page 81). Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning NN43041-311 04.01 4 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 81 XTRK DB32 32-port DSB daughterboard. CUST The customer to which the IPTN resources are assigned. Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning NN43041-311 04.01 4 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 82: Configuring The Dtr

    For detailed instructions on configuring the DTR, see Communication Server 1000E Installation and Commissioning (NN43041-310). Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning NN43041-311 04.01 4 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 83: Configure An E1/T1 Card

    Procedure 29 “Configuring PRI and PRI2 trunks with Trunk Data Block data using LD 14” (page 100) Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning NN43041-311 04.01 4 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 84: Configure E1/T1 Ports On A Call Server

    When you configure E1/T1 ports on a Call Server, you must configure: • PRI, PRI2, and DPNSS/DASS trunk loops • PRI, PRI2, and DPNSS/DASS D-channels Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning NN43041-311 04.01 4 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 85: Pri Digital Trunk Loop Configuration

    PRI Gateway, card 1-8 is applicable. MODE Mode of operation. TMDI TMDI functionality is not supported for MGP gateway. Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning NN43041-311 04.01 4 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 86 LD 17 needed to support DPNSS loops (common equipment parameters) on the PRI Gateway. Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning NN43041-311 04.01 4 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 87: D-Channel Configuration

    However, PRI D-channel in the PRI Gateway is also supported on other interface types as well. Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning NN43041-311 04.01 4 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 88 D-channel configuration on MSDL card. MSDL= NTBK51AA/NTBK51CA downloadable D-channel daughterboard. TMDI is not supported for MGP. Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning NN43041-311 04.01 4 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 89 Enter the responses shown in Table 20 "PRI2/Euro D-channel interface configuration (LD 17)" (page 90). Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning NN43041-311 04.01 4 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 90 Step Action Log on to the CS 1000E. To access LD 17, enter: LD 17 Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning NN43041-311 04.01 4 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 91 D-channel daughterboard (port 0 and port 1) simulated through the physical location of card 4. Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning NN43041-311 04.01 4 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 92 Port 1 of the NTBK51AA/NTBK51CA daughterboard handles the interface. DCHL The E1 loop served by this interface (201). Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning NN43041-311 04.01 4 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 93: Dpnss/Dass Configuration - Ddsl Data Blocks

    These prompts are enabled when the IPMG package (package number 403) is enabled, regardless of the state of the softswitch package. Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning NN43041-311 04.01 4 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 94 - PREF Card Card number of PRI containing the Primary Clock Reference for the second IPMG. Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning NN43041-311 04.01 4 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 95 - PREF Card Card number of PRI2 containing the Primary Clock Reference for the first IPMG. Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning NN43041-311 04.01 4 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 96 Automatic reporting of CRC-4 error. ALRM Default alarm handler selected (aaa = REG or ALT). Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning NN43041-311 04.01 4 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 97: Configure Pri, Pri2 And Dpnss Routes

    Route number. Range the same as for Large System and CS 1000E system. TKTP Trunk type. DTRK Digital trunk route. Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning NN43041-311 04.01 4 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 98 0 - 511 Route number. Range the same as for Large System and CS 1000E system. Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning NN43041-311 04.01 4 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 99 DPNSS/DASS Route (LD 16) Prompt Response Description Request (aaa = CHG, NEW) TYPE Route Data Block. Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning NN43041-311 04.01 4 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 100: Configure Pri, Pri2 And Dpnss Trunks

    Trunk Data Block data for PRI and PRI2 trunks (LD 14) Prompt Response Description Request (aaa = CHG, NEW) TYPE Trunk data block. Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning NN43041-311 04.01 4 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 101 Log on to the CS 1000E. Enter the command: LOGI System response: USERID? Enter the username. System response: PASS? Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning NN43041-311 04.01 4 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 102 Return to the Routes and Trunks » D-Channels page. Click the MSDL Diagnostics (LD 96) link. The MSDL Diagnostics page appears. Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning NN43041-311 04.01 4 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 103 Real/virtual digital channel. l ch Terminal Number for digital trunks where l = loop, ch = channel. Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning NN43041-311 04.01 4 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 104: Enable Pri Spans

    To enable the clock controller, follow the procedure described in Procedure 35 “Enabling the clock controller” (page 105). Procedure 33 Enabling the NTBK51AA/NTBK51CA daughterboard Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning NN43041-311 04.01 4 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 105 ENBL ACTIVE. All configured channels are normally enabled. --End-- Procedure 35 Enabling the clock controller Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning NN43041-311 04.01 4 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 106: Initial Configuration Of The E1/T1 Card

    Power up the system. Enter the LAN settings. For detailed information, see “Configure LAN parameters” (page 108). Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning NN43041-311 04.01 4 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 107 • secondary • free run The Status displays the span status: either enabled or disabled. Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning NN43041-311 04.01 4 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 108 Press enter for the password. To move to the system administration directory, enter the command: cd sadmin Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning NN43041-311 04.01 4 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 109 To restart the card, when you see the prompt Restart the card?, enter this command: --End-- Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning NN43041-311 04.01 4 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 110 Verifying a network connection from the CLI Step Action To log on to the system, enter this command: admin Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning NN43041-311 04.01 4 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 111 112). An example of no connection is shown in Figure 24 "Ping results of no E1/T1 connection to ELAN subnet" (page 112). --End-- Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning NN43041-311 04.01 4 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 112: Remote Access To The E1/T1 Card

    (null modem) is required as shown in Figure 25 "Modem connection" (page 113). Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning NN43041-311 04.01 4 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 113: Initial Configuration Of An E1/T1 Card Through The Command Line Interface

    Connect the RS-232 serial port (D-type 9 pins) to a terminal or a PC with terminal emulation (for example, HyperTerminal). Configure the interface to: Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning NN43041-311 04.01 4 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 114: Access And Configure An E1/T1 Card Through The Web

    Procedure 42 “Accessing the basic parameters for the E1/T1 card through the Web” (page 115). Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning NN43041-311 04.01 4 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 115 Click Login. The dialog box shown in Figure 27 "Logon dialog box" (page 116) appears. Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning NN43041-311 04.01 4 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 116: Define Administrative Users

    You can define a maximum of 10 administrative users. See Procedure 43 “Adding administrative users through the Web” (page 117). Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning NN43041-311 04.01 4 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 117: View And Change Administrative User Settings

    List in the left pane. The window shown in Figure 30 "View the User List window" (page 118) appears. Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning NN43041-311 04.01 4 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 118 Figure 31 "Edit User Attributes window" (page 118) appears. Figure 31 Edit User Attributes window --End-- Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning NN43041-311 04.01 4 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 119: Change Password

    The administrator completes the basic parameters for the E1/T1 card. See Procedure 46 “Configuring basic parameters for an E1/T1 card through the Web” (page 120). Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning NN43041-311 04.01 4 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 120 E1/T1 card uses to identify itself (the default is MGP@company.com). This is the e-mail address that appears in Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning NN43041-311 04.01 4 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 121: Configure Isdn E1/T1 Trunks

    The window shown in Figure 34 "E1/T1 Settings window" (page 121) appears. Figure 34 E1/T1 Settings window Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning NN43041-311 04.01 4 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 122 For each E1 span, configure the parameters as described in Table 34 "Parameters for E1 spans" (page 123). Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning NN43041-311 04.01 4 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 123 120 ohm Shield Ground No—for 75 Ohm only e To save the parameters, click Submit. --End-- Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning NN43041-311 04.01 4 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 124 124 Configure an E1/T1 card Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning NN43041-311 04.01 4 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 125: Maintenance And Diagnostics

    To see maintenance and diagnostic information for the E1/T1 card, see “Reports, upgrades, and backups” (page 137). Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning NN43041-311 04.01 4 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 126: Maintain Pri Digital Trunk Loops

    DLBK l ch Disable remote loop back test. RCNT Reset alarm counters of all DTi/PRI loops. Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning NN43041-311 04.01 4 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 127: Maintain Downloadable D-Channels

    Procedure 50 “Maintaining the DDCH using LD 96” (page 127). Procedure 50 Maintaining the DDCH using LD 96 Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning NN43041-311 04.01 4 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 128: Pri Startup

    Procedure 51 Starting up the PRI Step Action Check the status of all PRI/PRI2 cards. Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning NN43041-311 04.01 4 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 129 If you do not get the DCH EST time and date response, enter EST DCH x. Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning NN43041-311 04.01 4 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 130 STAT DCH x To check the status of all PRI loops, enter: LD 60 STAT L Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning NN43041-311 04.01 4 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 131 STAT MDSL sl s c FULL Check that the PRI cables are connected to the E1/T1 span connectors. --End-- Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning NN43041-311 04.01 4 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 132: Maintain Dpnss/Dass And Dchi

    The message OK STARTING appears and you can enter more commands. The message DTM301 appears when the link starts successfully. --End-- Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning NN43041-311 04.01 4 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 133: Dpnss/Dass Startup And Status Check

    To enable the LAP protocols for each real and virtual channel configured on the DPNSS1/DASS2 link, enter: LD 75 Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning NN43041-311 04.01 4 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 134 (2, 4, 6, 8). The red LED is lit only when this port is disabled. Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning NN43041-311 04.01 4 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 135: Inventory Cards

    The card inventory prints out as shown in this example: PRI, 262, NTDW70AAE5 01 NNTML2???????????? Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning NN43041-311 04.01 4 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 136 Only E1/T1 cards and spans that are configured in the software are printed. Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning NN43041-311 04.01 4 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 137: Reports, Upgrades, And Backups

    Procedure 56 “Viewing and downloading reports” (page 138). The file format for error reports is simple text. Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning NN43041-311 04.01 4 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 138: Upgrades

    You can also perform an FTP upgrade from a CLI command. • file upload. See Procedure 58 “Performing a software upgrade through upload” (page 140). Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning NN43041-311 04.01 4 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 139 View Last Upgrade Details window. For more information, see “Check software upgrades” (page 140). --End-- Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning NN43041-311 04.01 4 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 140 Procedure 59 “Checking the status of software upgrades” (page 141). Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning NN43041-311 04.01 4 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 141: Backups And Restores

    FTP server. The format of the backup file is D1yymmdd.zip where: Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning NN43041-311 04.01 4 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 142: Automatic Backups

    = the two digits representing the day Because each backup file name contains the date, each file name is different and the files accumulate on the FTP server. Nortel recommends that you periodically delete old backup files. For information about how to check the status of backups, see “Check...
  • Page 143: Manual Backups

    Backups and restores 143 the day of the month from the list. Nortel recommends that you select the time in which the least activity occurs. Determine the destination of the backup (where and how the backup is sent). Select one of the following options: a Zip file sent by E-mail to admin address.
  • Page 144 (logon) and the password. Select Configuration data or Error Reports or both. Click Submit. --End-- Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning NN43041-311 04.01 4 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 145: Check Backup Status

    The View Backup History Log window displays one line (record) for each backup attempt with a status of either succeeded or failed. Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning NN43041-311 04.01 4 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 146: Restore Backups

    The window shown in Figure 47 "Execute Manual Restore window - FTP" (page 147) appears. Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning NN43041-311 04.01 4 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 147 You can view the details of the restore as shown in Figure 48 "View Last Restore Details window" (page 148). Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning NN43041-311 04.01 4 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 148 The window shown in Figure 49 "Execute Manual Restore window - Upload" (page 149) appears. Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning NN43041-311 04.01 4 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 149 You can view the details of the restore as shown in Figure 48 "View Last Restore Details window" (page 148). --End-- Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning NN43041-311 04.01 4 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 150 150 Reports, upgrades, and backups Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning NN43041-311 04.01 4 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 151: Cli Commands

    Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning NN43041-311 04.01 4 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 152 152 CLI commands Figure 50 Tree structure of CLI commands Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning NN43041-311 04.01 4 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 153: Pri Gateway Alarms

    ESF CRC6 errors CRC6 errors ESF - FEBE CRC6 errors reported by remote side Slip Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning NN43041-311 04.01 4 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 154 Loss of signal LFAS Lost frame alignment signal ESF – CLMAS Loss of CRC6 frame alignment signal Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning NN43041-311 04.01 4 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 155: Media Gateway Controller System Alarms, Events, And Messages

    Clear MGC <supl shelf> None TTY, LOG, (E002) registered to the Call SNMP, LED Server. Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning NN43041-311 04.01 4 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 156 MGC <supl shelf> - User None TTY, LOG, <LDS1/LDS2> has logged SNMP into the card. Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning NN43041-311 04.01 4 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 157 SRPT0174 Info STARTUP: “EXP_CAB” TTY, LOG, registration denied. SNMP Unconfigured IP address nnn.nnn.nnn.nnn. Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning NN43041-311 04.01 4 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 158 158 Media Gateway Controller system alarms, events, and messages Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning NN43041-311 04.01 4 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 159 DCH daughterboards 41 printing IDS for MGP cards 135 DCHI 132 IPE card slots 41 Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning NN43041-311 04.01 4 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 160 Web 114 Telnet 113 removing daughterboards 57 replaceable components 35 shelf slots 30 Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning NN43041-311 04.01 4 June 2010 Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
  • Page 162 While the information in this document is believed to be accurate and reliable, except as otherwise expressly agreed to in writing NORTEL PROVIDES THIS DOCUMENT "AS IS" WITHOUT WARRANTY OR CONDITION OF ANY KIND, EITHER EXPRESS OR IMPLIED. The information and/or products described in this document are subject to change without notice.

Table of Contents