376 Chapter 39 Hardware procedures
Procedure steps
Procedure job aid
NN10600-175 6.1S2
Table 4 (continued)
Typical line build out application settings
Gauge
Distance
5
6
(Sheet 2 of 2)
1
Lay the wires from the timing source up to the connectors on the BITS
termination panel. Route the wires up or down the right side of the frame
against the cable management brackets.
2
Connect the wires at the timing source, using whatever method of
connection is required.
3
Label each timing wire pair at both end points to distinguish which is
reference 0 and which is reference 1.
4
Fasten the wires snugly with tie-wraps to whatever CPE wire support
system leads to the cable management brackets on the mounting
apparatus. Leave enough length at termination panel end of the wire to
attach the D-sub or coax connectors.
5
Assemble the cable with the appropriate connector. Refer to the pinout
tables below.
Table 5
Pinouts of the connectors for DS1 or E1 balanced
Pin
DS1 for BITS-0
1
no connection
2
no connection
3
GND (ground)
4
no connection
5
BITSRX0P
6
no connection
(Sheet 1 of 2)
DS1 for BITS-1
no connection
no connection
GND (ground)
no connection
BITSRX1P
no connection
Transmitter
-7.5 db CSU
-15 db CSU