Intel® Server System M50CYP1UR Family System Integration and Service Guide
3.4.7
OCP* Adapter with Internal Lock Removal
1. Remove the system top cover (see
2. Remove any riser card assembly above the OCP* adapter area if present (see
3. Squeeze the two hooks of the internal lock and pull it out (see Letter A).
4. Install it back in the chassis in reverse orientation (see Letter B).
5. Push the OCP* adapter out of the bay from inside the chassis (see Letter C).
6. Reinstall the riser card assembly as needed (see
7. Reinstall the system top cover (see
3.5
M.2 Storage Device Installation / Removal
The server board includes two M.2 connectors as shown in the following figure. Each M.2 connector supports
a PCIe* NVMe* or SATA SSD drive that conforms to a 22110 (110 mm) or 2280 (80 mm) form factor.
Required Tools and Supplies
•
Anti-static wrist strap and conductive workbench pad (recommended)
•
Phillips* head screwdriver #1
Figure 48. OCP* Adapter with Internal Lock Removal
Section
3.1.1).
Section
3.1.2).
Figure 49. M.2 SSD Connector Location
Section
3.2.4).
Section
3.2.1).
49