3-1.

Malfunction detection timing and remedies

• If the problem cannot be corrected by the user, a service code is displayed.
(1)
FATAL ERROR CODE 04H: Malfunction of the master board
<Remedy>
Master board (PWB-A)
Step
Remedy
1
Replace PWB-A.
(2)
FATAL ERROR CODE 08H: Malfunction of the main motor
<Remedy>
Main motor (M1)
Step
Remedy
1
Check M1 operation.
3
Replace PU.
4
Replace PWB-A.
5
Replace PWB-P.
(3)
FATAL ERROR CODE 0BH: Malfunction of the ventilation fan motor
<Remedy>
Ventilation fan motor (M6)
Step
Remedy
1
Check M6 operation.
2
Replace PU.
3
Replace PWB-A.
4
Replace PWB-P.
Components for display of the warning
Reference
page
Control signal
-
Components for display of the warning
Master board (PWB-A)
Power unit (PU)
Controller control board (PWB-P)
Reference
page
Control signal
T-3
M1_REM
-
-
-
Components for display of the warning
Master board (PWB-A)
Power unit (PU)
Controller control board (PWB-P)
Reference
page
Control signal
T-3
M6_REM
-
-
-