Installation

6.1

Preparing the cable gland plate

Remove the protective cover
To make the cable gland plate accessible, first remove the bottommost protective cover in the
interior of the charging station:
1. Open the cabinet door.
To prevent the door from closing suddenly, fix it in place with suitable aids.
2. Unscrew the fastening screws of the bottom protective cover.
3. Remove the protective cover.
Preparing the cable gland plate
The figure below shows the cable gland plate.
Figure 6-1  Cable gland plate
1. Mark the drill holes for the cable glands.
2. Loosen the four fastening screws of the cable gland plate.
3. Remove the cable gland plate from the cabinet.
4. Drill the holes for all connecting cables in the size of the cable glands used.
5. Mount the cable glands.