Connecting

7.5 Connecting charge points to a single charging station

Connecting the auxiliary power supply
To connect the L and N cables of the auxiliary power supply, follow these steps:
1. Strip the insulation from the end of the conductor so that the remaining insulation
extends up to the ferrule.
2. Properly attach the wire end ferrule to the conductor end.
3. Connect the L conductor of the cable to the terminal "-FC30:2".
4. Connect the N conductor of the cable to the terminal "-FC30:4".
5. The tightening torque of the screw terminals is between 2.5 and 3 Nm.
You can find the terminal designations and the connection plan in the circuit diagram and
here (Page 150).
Sealing
Seal cable openings and other openings with permissible sealing material. Permissible sealing
material includes silicone and soft PU foam.
7.5
Connecting charge points to a single charging station
7.5.1

UC Dispenser

This section provides an overview of the connection of a SICHARGE UC Dispenser to a
SICHARGE UC150 charging station.
88
Operating Instructions, 02/2023, A5E50068475-AB
SICHARGE UC 150