3. Remove the 6 hexagon head screws
Figure 11-3 Lower air filters
4. Pull out the fan unit
Figure 11-4 Removing the fabric filters
5. Insert the new fabric filters into the filter holder.
6. Swing the air filter unit back and slide it into the filter box.
7. Screw down the 6 hexagon head screws with a tightening torque of 8 Nm.
8. Set the circuit breaker to the "ON" position.
9. Close and lock the door of the charging station.
SICHARGE UC 150
Operating Instructions, 02/2023, A5E50068475-AB
①
.
②
. Swing the fan unit up
Maintenance and service
11.3 Servicing the charging station
③
. Remove the two used fabric filters
④
.
141