Operation
9.3 Operation via HMI
Advanced settings
Information and setting options for each charging port are shown in the area "Advanced
settings". To open the area, select the "Advanced settings" button in the Settings (Page 122).
Figure 9-13  Advanced settings
If there are several dispensers, select the one you require using the drop-down menu.
The following information is displayed:
Table 9-1  Information about the electricity supply
Section
Voltage
L1-L2
Voltage between the phases in Volt
L2-L3
Voltage between the phases in Volt
Output
Voltage at the output in Volt
DC link voltage
Voltage in the DC link
Frequency
Line frequency in Hz
Table 9-2  Information about temperature
Section
Temperature
Fan control system
Temperature at the fan control
IGBT
Temperature at the power switch modules
126
Current
Current between the phases in Ampere
Current between the phases in Ampere
Current at the output in Ampere
Speed
Fan speed in % of the maximum speed
To change the maximum fan speed, press the
text box and enter a value using the numeric
keypad.