Siemens SICHARGE UC 150 Operating Instructions Manual page 144

Hide thumbs Also See for SICHARGE UC 150:
Table of Contents

Advertisement

Maintenance and service
11.4 Replacing a cabinet fan
Position of the cabinet fan
Figure 11-6  Position of the cabinet fan
Removing a cabinet fan
Only replace a cabinet fan when the charging station is in error mode or repair mode.
To remove the cabinet fan, proceed as follows:
1. Open the door of the charging station.
2. Set the circuit breaker to the "OFF" position.
3. Disconnect the connecting cables of the fan.
4. Unscrew the fastening screws of the cabinet fan.
5. Pull out the cabinet fan.
Install a new cabinet fan
To install the cabinet fan, proceed as follows:
1. Insert the cabinet fan.
2. Tighten the fastening screws of the cabinet fan.
3. Connect the connecting cables of the fan.
4. Set the circuit breaker to the "ON" position.
5. Close the door of the charging station.
144
Top cabinet fan
Cabinet fan in the door
Operating Instructions, 02/2023, A5E50068475-AB
SICHARGE UC 150