Preparing for use
5.5 Checking incoming goods
Included items
These items are included with the charging station.
• 1x USB flash drive for software installation for each group (order) of charging stations
• 2x Teltonika SIM card adapter
• Front cover of the base frame
• Back cover of the base frame
• 2x door key for each charging station
• 2x mounting bracket for the charging station
5.5.2

Checking the transport packaging

Start the inspection of the transport packaging with a visual inspection of the shock indicator.
Checking the shock indicator
During transport, a transport pallet with shock absorbers protects the charging station from
shocks and vibrations. However, the effect of extreme G-forces can overload the shock
absorbers. A shock indicator is attached to the transport packaging of the charging station to
detect the occurrence of such a damaging event.
Figure 5-13  Schematic example: Shock indicator
The shock indicator monitors any G-forces acting during the entire transport. If the charging
station is subjected to unacceptably high G-forces during transport, the shock indicator is
triggered. The indicator tube shows that the tolerance limit for G-forces has been exceeded
by red coloring.
Perform a visual inspection of the shock indicator as follows:
1. Check whether there is a shock indicator on the transport packaging.
2. Check whether the glass tube in the middle of the indicator has turned red.
3. Report any red colored or missing indicator to the carrier immediately.
The carrier must confirm the red colored or missing indicator on the receipt.