Installation and mounting

5.1

Preparation

Tools list
Ensure that before beginning work all required tools, materials and lifting gear is available.
The following list does not claim to be complete:
• Personal protective equipment (PPE) (Page 11)
• Fall arrester (Page 11)
• Crane
• Drill hammer
• Drilling machine
• 12 mm drill bit for concrete
• 4 units M12 stud bolts with approx. 50 mm long thread
• 4 units nuts M12 DIN 934
• 4 units spring washers M12
• 4 units spring washers M12 DIN 125
• Shims for alignment
• Step drill
• Cable knife
• Press tool for cable lug M10
• Torque wrench up to 70 Nm
• Torque wrench up to 10 Nm
• Socket wrench set up to at least 19 mm width across flats
• Ring wrench set up to at least 19 mm width across flats
• Allen key 5 mm
• Torx screwdriver TX30
• Hammer
• Spirit level
• Stepladder
• Hot air gun
• Shrink-on sleeve for cable diameter used
• Cable lugs of size M8 with a maximum width of 32 mm for the used conductor cross-
section
As an example from the company Klauke:
– Mount 11SG8 for cables up to 185 mm
– Mount 12SG10 for cables up to 240 mm
– Mount 13SG10 for cables up to 300 mm
• Folding ruler
• Permanent marker
• Two-pole voltage tester
Dispenser
Operating Instructions, 10/2023, A5E52758387-AB
2
with M8 screw
2
with M8 screw and large washer
2
with M8 screw and large washer
5
37