7.6 Connecting charge points to a multi-charging station
Table 7-15  Connection table for 230 V AC AUX
Parent charging sta­
tion
IN
AUX-L
AUX-N
AUX-L
AUX-N
1
= This column is valid only for a UC450 and UC600
2
= This column is valid only for a UC600
The DC shutdown is wired from one charging station to the next in series.
NOTE
Important information on the DC shutdown
• Each charging station DC shutdown button switches off the DC voltage on all charging
stations connected in parallel.
• A global DC shutdown button switches off the DC voltage on all charging stations
connected in parallel.
• Connect the jumpers at the left and right ends of the charging stations connected in
parallel.
Table 7-16  Connection table for DC shutdown
Parent charging station
IN
L
3
L
3
1
= This column is valid only for a UC450 and UC600
= This column is valid only for a UC600
2
3
Jumper for global DC shutdown
The following table shows where you connect the jumper, depending on whether a DC
shutdown has been installed.
Table 7-17  Jumper for global DC shutdown
Shutdown on the MastPanto
No
Yes
106
Child charging station
OUT
IN
OUT
-XD10:1:C
-XD10:1:A
-XD10:1:C
-XD10:6:C
-XD10:6:A
-XD10:6:C
Child charging station
OUT
IN
-XD10:4:A
-XD10:2:A
-XD10:3:C
-XD10:3:A
Left end of the charging station series
-XD10:1 = -XD10:2
-XD10:2 = -XD10:3
1
Child charging station
IN
OUT
-XD10:1:A
-XD10:1:C
-XD10:6:A
-XD10:6:C
1
Child charging station
OUT
IN
-XD10:4:A
-XD10:2:A
-XD10:3:C
-XD10:3:A
Right end of the charging station series
-XD10:3 = -XD10:4
-XD10:4 = -XD10:5
Operating Instructions, 02/2023, A5E50068475-AB
2
Child charging station Mast­
IN
OUT
-XD10:1:A
-XD10:6:A
-XD10:1:D -XD02:L
-XD10:6:D -XD02:N
2
Child charging station
OUT
IN
-XD10:4:A
-XD10:2:A
-XD10:3:C
-XD10:3:A
SICHARGE UC 150
Panto
IN
OUT
3
3