6 Commissioning

6.1 Lift Sequences

HW Enable
Start / Rev cmd
Mlt spd s 0
Mlt spd s 1
Mlt spd s 2
Speed ref 1
Magn. current

6.2 Preliminary Operations

Menu
4.3
The drive can be configured in two modalities, Easy (only the main parameters are displayed) and Expert (all parameters are
displayed). The mode can be selected by parameter:
6.2.1

Set the motor type

Menu
Parameter
4.19
6100
If a different type is selected, the drive must be switched off and then switched on.
6.2.2

Set the units for the car speed

Menu
5.1.1
To select m/s set to 1, in rpm (speed of the motor shaft) set to 2, in feet per minute set to 3.
ADL300 - Fast installations and commissioning
Acc end jerk
Acceleration
Acc ini jerk
Run Cont Close delay
Brake open delay
Parameter
Description
554
Access Mode
Description
Load Async / Sync Control
Parameter
Description
11002
Travel Units sel (Hz, m/s, rpm)
Dec ini jerk
Deceleration
Dec end jerk
Spd 0 ref thr
Slow Down dist
Spd 0 ref delay
Run Cont open delay
Brake close dly
Default Value
Easy
Default Value
Default Value
0
End decel
Set to
Expert
Set to
Async or Sync
Set to
1-2-3