Polaris RZR 900 2017 Service Manual page 570

Hide thumbs Also See for RZR 900 2017:
Table of Contents

Advertisement

ELECTRICAL
To change between Standard and Metric units of
measurement, follow these steps:
1. Turn the key to the OFF position.
2. Press and hold the MODE button while turning the
key to the ON position.
3. When the display flashes the distance setting, tap the
MODE button to advance to the desired setting.
4. Press and hold the MODE button to save the setting
and advance to the next display option.
5. Repeat the procedure to change remaining display
settings.
12.10
Under / Over Voltage
This warning usually indicates that the vehicle is
operating at an RPM too low to keep the battery charged.
It may also occur when the engine is at idle and a high
electrical load is applied (lights, cooling fan or other
accessories).
If battery voltage drops below 11 volts, a warning screen
will display "Lo" and provide the present battery voltage.
If voltage drops below 8.5 volts, LCD backlighting and
icons will turn off.
If battery voltage rises above 15 volts, a warning screen
will display "OV" and provide the present battery voltage.
If voltage rises above 16.5 volts, LCD backlighting and
icons will turn off.
9930588 R02 - 2017-2020 RZR 900 900/S 900/S4 1000/S 1000/S4 Service Manual