Polaris RZR 900 2017 Service Manual page 217

Hide thumbs Also See for RZR 900 2017:
Table of Contents

Advertisement

24. MECHANICAL TENSIONER ONLY:
• Retract the plunger all the way in and install into the
cylinder.
• Install the two mounting bolts. Torque fasteners to
specification.
TORQUE
Tensioner Mounting Bolts:
7 ft-lb (10 Nm)
• Install the plunger bolt. Torque fastener to
specification.
TORQUE
Plunger Bolt:
15 ft-lb (20 Nm)
25. Rotate crankshaft through two revolutions and verify
camshaft timing is correct.
9930588 R02 - 2017-2020 RZR 900 900/S 900/S4 1000/S 1000/S4 Service Manual
© Copyright Polaris Industries Inc.
ENGINE / COOLING SYSTEM
3
3.83

Advertisement

Table of Contents
loading

Table of Contents