MAINTENANCE

ELECTRICAL / IGNITION SYSTEM

BATTERY MAINTENANCE

Keep battery terminals and connections free of
corrosion. If cleaning is necessary, remove the corrosion
with a stiff wire brush. Wash with a solution of one
tablespoon baking soda and one cup water. Rinse well
with tap water and dry off with clean shop towels. Coat
the terminals with dielectric grease or petroleum jelly.
CALIFORNIA PROPOSITION 65 WARNING:
Batteries, battery posts, terminals and related
accessories contain lead and lead compounds, and
other chemicals known to the State of California to
cause cancer and birth defects or other reproductive
WASH HANDS AFTER HANDLING.
Battery electrolyte is poisonous. It contains sulfuric
acid. Serious burns can result from contact with skin,
eyes or clothing. Antidote:
• External: Flush with water.
• Internal: Drink large quantities of water or milk.
Follow with milk of magnesia, beaten egg, or
vegetable oil. Call physician immediately.
• Eyes: Flush with water for 15 minutes and get
prompt medical attention.
Batteries produce explosive gases.
Keep sparks, flame, cigarettes, etc. away. Ventilate
when charging or using in an enclosed space. Always
shield eyes when working near batteries.
KEEP OUT OF REACH OF CHILDREN.
NOTICE
Batteries must be fully charged before use or battery
life will be reduced by 10-30% of full potential. Charge
battery according to "Charging Procedure" page
not use the vehicle's stator/alternator to charge a new
2.58
WARNING
harm.
WARNING
battery.

BATTERY OFF SEASON STORAGE

Whenever the vehicle is not used for a period of two
months or more, remove the battery from the vehicle,
ensure that it is fully charged, and store it out of the sun
in a cool, dry place. Check battery voltage each month
during storage and/or recharge as needed to maintain a
full charge.
Battery charge can be maintained by using a Polaris
battery tender charger or by charging once a month to
make up for normal discharge. Battery tenders can be
left connected during the storage period and will
automatically charge the battery if the voltage drops
below a pre-determined point.

BATTERY CHARGING

If battery voltage is less than 12.6 Vdc, the battery may
need recharging. When using an automatic charger, refer
to the charger manufacturer's instructions for recharging.
Do not exceed 6 amps when charging the battery.
Charge the battery using an automatic charger that will
not exceed 14.6 Vdc. An automatic charger will signal
when charging is complete.
Allow the battery to stand disconnected for at least 1 –
2 hours after being properly charged. If the voltage
drops below 12.6 volts, charging was ineffective or the
battery needs to be replaced.
Always watch charging times carefully. An overheated
battery could explode, causing severe injury or death.
Stop charging if the battery becomes very warm to the
touch. Allow it to cool before resuming charging.
. Do
VOLTAGE
STATE OF
(DC)
CHARGE
12.8 or
100%
more
75% -
12.6 - 12.8
100%
50% - 75%
12.3 - 12.6
9930588 R02 - 2017-2020 RZR 900 900/S 900/S4 1000/S 1000/S4 Service Manual
NOTICE
NOTICE
WARNING
CHARG-
ACTION
E TIME
None, check
None
again in 3
Required
months
May need
3 - 6 hrs
slight charge
Needs
5 - 11 hrs
Charge