2.3 Standard Removal Procedures

To remove the board proceed as follows:
1. Ensure that the safety requirements indicated in chapter 2.1 Safety Requirements are observed.
Care must be taken when applying the procedures below to ensure
that neither the CP6930 nor other system boards are physically dam-
aged by the application of these procedures.
2. Ensure that no power is applied to the system before proceeding.
3. Disconnect any interfacing cables that may be connected to the board.
4. Unscrew the front panel retaining screws.
Due care should be exercised when handling the board due to the fact
that the heat sink can get very hot. Do not touch the heat sink when
changing the board.
5. Disengage the board from the backplane by first unlocking the board ejection handles and then by
pressing the handles as required until the board is disengaged.
6. After disengaging the board from the backplane, pull the board out of the slot.
7. Dispose of the board as required.

2.4 Software Installation

The CP6930 comes as a pre-installed system with all necessary OS, filesystem, drivers and applications fac-
tory-installed with default configurations.
Updating the Software with new operating system or applications or new versions is provided by a dedicated
update mechanism, which is described in Chapter 4.

2.5 Quick Start

This section gives instructions for (initially) accessing the CLI (Command Line Interface) of the CP6930 using
either in-band access via the ethernet fabric or the out-of-band management interfaces (serial port or Fast
Ethernet) accessible from the front plate serial connector or via an appropriate RIO module. The CLI is
required for configuring the GbE switch.