1.3.5 Humidity

The board is designed to meet Bellcore GR63, Section 4.1
• Operating: 93% (non-condensing) at 40°C
• Non-Operating: 5%-95% (non-condensing) at 40°C

1.3.6 Altitude

The board is designed to meet the following requirements:
• Operating: 15000 ft, additional cooling might be required above 6000ft
• Non-Operating: 60000 ft

1.3.7 Vibration

The board is designed to meet the following requirements:
• Standard
• DIN/IEC 60068-2-6 (Sine)
• ANSI/Vita 47-2005, Environmental class EAC1
• Bellcore GR-63, Section 4.4
• 10Hz to 300Hz, Acceleration: 2 g, Test Cycle: 1 oct./min., Cycle Count: 10/axis, 3 axis
• 5 Hz to 100 Hz Power Spectral Density (PSD) = 0.04 g2/Hz

1.3.8 Bump

The board is designed to meet the following requirements:
• Standard
• DIN/IEC 60068-2-29
• Peak Acceleration: 15 g, Shock Duration: 11 ms half sine, Shock Counts: 500/direction, Recovery Time:
1 s

1.3.9 Shock

The board is designed to meet the following requirements:
• Standard
• DIN/IEC 60068-2-27
• Peak Acceleration: 30 g, Shock Duration: 9 ms half sine, Recovery Time: 5 s, Shock Count: 3/direction,
6 directions