Config file 'current/startup-config' created successfully.
Configuration Saved!
(Ethernet Fabric) #
To access the CLI via Fast Ethernet serviceport, open a telnet connection to the configured IP address, port
23.

2.5.2 In-Band CLI Access

The GbE switch network port (in-band management access) on the CP6930 has no IP address set by default,
it is necessary to assign an IP address either statically or by using DHCP to the network port. Because the
required configuration steps are done in the CLI, an initial access using the serial port is required.
The procedure for assigning an IP address to the network port is described in the following. User input is
printed in bold letters.
1. Connect to serial port on the front plate (using the Kontron DB9 adapter cable) or RIO module (using a
RJ45 straight cable).
2. Ensure that the board is powered up.
3. Log in as admin and enter privileged mode by typing 'enable' (no passwords required by default).
User:admin
Password:
(Ethernet Fabric) >enable
Password:
(Ethernet Fabric) #
4. Set IP address, netmask and default gateway. (see below for an example IP address setting)
(Ethernet Fabric) #network parms 192.168.50.107 255.255.255.0 192.168.50.254
The GbE management interface is available from now on.
Alternatively, DHCP can be set for the network port
(Ethernet Fabric) #network protocol dhcp
An IP address will be given to the network port by a DHCP server.
5. Save configuration by using the 'write mem' command and confirm 'y'
(Ethernet Fabric) #write mem
This operation may take a few minutes.
Management interfaces will not be available during this time.
Are you sure you want to save? (y/n) y
Config file 'current/startup-config' created successfully.
Configuration Saved!
(Ethernet Fabric) #