Table 4-7:
Sensor List (Continued)
Sensor Number / ID
string
43 / POST Value
C6h (Kontron OEM )
44 / Boot Error
1Eh (Boot Error)
45 / System Upgr
CAh (Firmware Upgrade Status)
46 / Memory State
24h (Platform Alert)
4.4.2.2
Sensor Thresholds
Following tables show sensor thresholds for temperature, voltage and current sensors.
Table 4-8:
Temperature Sensor Thresholds [°C]
SENSOR Number/ ID
Lower criti-
string
13 / Temp-PCB1
NA
14 / Temp-PCB2
NA
15 / Temp-PCB3
NA
16 / Temp-PHY1
NA
17 / Temp-PHY2
NA
18 / Temp-PHY3
NA
Table 4-9:
Voltage/Current Sensor Thresholds
SENSOR Number / ID
Lower criti-
string
19 / Vcc5.0vCPCI
4.76 V
20 / Icc5.0vCPCI
NA
21 / Vcc3.3vCPCI
3.14 V
22 / Icc3.3vCPCI
NA
23 / Vcc3.3vCPLD
3.14 V
24 / Vcc3.3vSUS
3.14 V
25 / Vcc3.3v
3.14 V
26 / Vcc2.5v
2.38 V
27 / Vcc1.8v
1.72 V
28 / Vcc1.25v
1.20 V
29 / Vcc1.2vCORE
1.18 V
Sensor Type (CODE)
Lower non
Nominal
cal
critical
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
Lower non
Nominal
cal
critical
NA
5.00 V
NA
NA
NA
3.30 V
NA
NA
3.30 V
NA
3.30 V
NA
3.30 V
NA
2.50 V
NA
1.80 V
NA
1.23 V
NA
1.21 V
61
Event Type Code / Event Offsets
Event Type: 6Fh (Sensor Specific)
Offset 0Eh: POST Error
Event Data 2: POST code
Event Type: 6Fh (Sensor Specific)
Refer to IPMI v1.5
Event Type: 6Fh (Sensor Specific)
Offset 0: Firmware upgrade in progress
Offset 1: Firmware upgrade succeeded
Event Type: 6Fh (Sensor Specific)
Offset 0: memory clear finished
Offset 1: memory clear not finished
Upper non
Upper criti-
critical
cal
75
85
60
65
65
70
115
125
115
125
115
125
Upper non
Upper criti-
critical
cal
NA
5.24 V
NA
9.94 A
NA
3.46 V
NA
9.75 A
NA
3.46 V
NA
3.46 V
NA
3.46 V
NA
2.63 V
NA
1.89 V
NA
1.26 V
NA
1.24 V
www.kontron.com
Software Description
Upper Non
Recoverable
95
70
75
135
135
135
Upper Non
Recoverable
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
CP6930 User Guide