6.2 Power Consumption
Typical idle and maximum traffic (all ports, maximum speed) conditions power values were measured.
Note...
The power consumption values indicated in the tables below can vary depending
on the ambient temperature or the system performance. This can result in devia-
tions of the power consumption values of up to 10%.
Table 6-3:
Input Current and Power
5V input current/A
Idle
3.9
Max. Traffic
6.7
6.3 Start-up Currents
The start-up currents of the CP6930 during the first 2-3 seconds after power has been applied (power-on or
hot-swap insertion) are less than the maximum currents given in Table 6-3 for each of the variants.
3V3 input current/A
4.6
34.7
7.3
57.6
76
Power Considerations
Total power /W
CP6930 User Guide
www.kontron.com