Intel SBCEFCSW Hardware Maintenance Manual page 113

Server switch module and fc expansion card
Hide thumbs Also See for SBCEFCSW:
Table of Contents

Advertisement

Figure 13. Zonesets Data window
The Configured Zonesets Data window uses display conventions for expanding and contracting
entries that are similar to the fabric tree. An entry handle to the left of an entry in the tree indicates
that you can expand the entry. Click this handle or double-click the following entries to expand or
contract them:
• A zone set entry expands to show its member zones.
• A zone entry expands to show its members by port number, worldwide name, or Fibre Channel
address.
Alarm Log Data window
The Alarm Log Data window displays switch module event information. To open the Alarm Log
Data window, click the Alarm Log tab below the data window in the Faceplate window.
Managing alarms
You can configure the switch module to generate and log alarms. To display the Alarm Log, click the
Alarm Log tab in the Faceplate window. For information about the alarm log, see "Alarm Log Data
window." You can also export the alarm log to a file in XML format.
Configuring alarms
Configuring an alarm involves choosing an event type, rising and falling thresholds, a sampling
interval, and then enabling or disabling the alarm.
Complete the following steps to configure an alarm:
1. In the Faceplate window, click Switch → Configure Alarm Thresholds.
2. The Alarm Threshold Configuration window shown in Figure 14 on page 100 prompts you to
select an event, set thresholds, set a sampling interval, and enable or disable the alarm.
Intel® Server Switch Module SBCEFCSW
99