Table 20. Switch data window entries (continued)
Entry
Security enabled
Vendor
Flash version
Inactive flash version
PROM/Flasher version
MAC address
IP address
Subnet mask
Gateway
Negotiated domain ID
Configured domain ID
Domain ID lock
Number of ports
Switch type
Operational state
Administrative state
Configured Admin State
MFS timeout
RA timeout
RT timeout
ED timeout
Zoning merge mode
Zoning merge auto save
Zoning default visibility
Temperature
Fan 1 status
Fan 2 status
Fan 3 status
Power supply 1 status
Power supply 2 status
Beacon status
Broadcast support
Intel® Server Switch Module SBCEFCSW
Description
Fabric security on the switch module that enforces account names and
passwords
Switch module manufacturer
Active flash
Inactive firmware version
Firmware version
Media access control address
Internet protocol address
Mask that determines the IP address subnet
Gateway address
The domain ID currently in use by the fabric
The domain ID defined by the network administrator
Domain ID lock status. Prevents (True) or permits (False) dynamic domain ID
reassignment
Number of ports on the switch module
Fibre Channel switch module model
Switch module operational state: Online, offline, and diagnostic
Current switch module administrative state: Online, offline, and diagnostic
Switch module administrative state that is stored in the switch configuration
Multiframe sequencing timeout value
Resource allocation timeout value
Receiver transmitter timeout value
Error detect timeout value
Active zone set merge or all zone set merge
Zoning auto save status. Saves zoning updates in temporary and permanent
memory (True) or only in temporary memory (False).
Zoning visibility status. Permits (ALL) or prevents (None) communication with
other switch modules in the absence of an active zone set.
Not applicable
Not applicable
Not applicable
Not applicable
Not applicable
Not applicable
Beacon status. Port Logged-in LEDs are flashing (On) or not (Off).
Broadcast support status. Broadcast support is enabled or disabled (default).