2. Click Edit → Create Zone Set.
The Create Zone Set window opens.
3. Type a name for the zone set, and click OK. The new zone set name is displayed in the Zone
Sets window.
4. Complete one of the following tasks to create new zones in a zone set:
• Right-click a zone set and select Create A Zone from the pop-up menu. In the Create A
Zone window, type a name for the new zone, and click OK. The new zone name is displayed
in the Zone Sets window.
• To copy an existing zone into the new zone set, in the Faceplate window, select the zone and
drag it into the new zone set.
5. Click Apply to save changes to the zoning database.
Activating and deactivating a zone set
You must activate a zone set to apply its zoning definitions to the fabric. Only one zone set can be
active at one time. When you activate a zone set, the switch module distributes that zone set to the
temporary zoning database on every switch in the fabric, replacing any zone set of the same name. If
Auto Save is enabled, the zone set is saved in the permanent zoning database also. For more
information, see "Auto save" on page 85.
The purpose of the deactivate function is to suspend all fabric zoning, which results in free
communication fabric-wide or no communication, depending on the default visibility setting. For
more information, see "Default visibility" on page 86. It is not necessary to deactivate the active
zone set before activating a new one.
Complete the following steps to activate a zone set:
1. In the Faceplate window, click Zoning → Activate Zone Set.
The Activate Zoneset window opens.
2. In the Select Zone Set menu, click Zone Set → Activate.
Complete the following steps to deactivate a zone set:
1. In the Faceplate window, click Zoning → Deactivate Zone Set.
A message warning you about traffic disruption is displayed.
2. Click Yes to confirm that you want to deactivate the active zone.
Copying a zone to a zone set
Complete the following steps to copy an existing zone and its membership from one zone set to
another:
1. In the Faceplate window, select the zone and drag it to the zone set you want.
2. Click Apply to save your changes to the zoning database.
Removing a zone from a zone set or from all zone sets
Complete the following steps to remove a zone from a zone set or from all zone sets in the database:
1. In the Faceplate window, click Zoning → Edit Zoning.
The Edit Zoning window opens.
2. In the Zone Sets tree, select the zone you want to remove.
3. Click Edit → Remove to remove the zone from the zone set, or select Remove from All Zones
to remove the zone from all zone sets.