Restoring Fibre Channel switch module configuration

This section describes switch module configuration restoration tasks that are performed using the
Telnet CLI interface and the management module.
Configuration backup
Changes made to the switch module since it was manufactured can be saved to a file in nonvolatile
memory. However, the backup file is lost if the switch module is reset. Use the File Transfer Protocol
(FTP) user images procedures to save the configdata file to the network management workstation.
(In FTP, no directory listing is available. The configuration backup file is always named configdata.)
For information about SNMP configuration, see "SNMP configuration" on page 122 and "SNMP
trap configuration" on page 122.
Configuration restore
Switch module configurations can be duplicated to easily propagate an identical configuration to
other switch modules. Use the FTP User Images procedures with the Put command to send the
previously saved (using config backup) configdata file to the switch module. In Telnet, use the
Config Restore command to return the switch module configuration to the previously saved
configuration. The switch module is automatically reset after a successful restore.
Restoring the factory default configuration
You can restore the switch module and port configuration settings to the factory default values. To
restore the factory configuration on a switch module, click Switch>Restore Factory Defaults.
Table 36 lists the factory default switch module configuration settings. Restoring the switch module
to the factory default configuration does not restore the login name and password settings.
Table 36. Factory default configuration settings
Settings
Module name
Administrative state
Domain ID
Resource allocation time
out (RA_TOV)
Receiver transmitter
timeout (RT_TOV)
Error detect timeout
(ED_TOV)
IP address
Subnet mask address
Gateway address
Boot method
Contact
Location
Intel® Server Switch Module SBCEFCSW
Value
Fibre Channel switch module
Online
1
10000 milliseconds
100 milliseconds
2000 milliseconds
I/O module bay 3: 192.168.70.129
I/O module bay 4: 192.168.70.130
255.255.255.0
10.90.90.254
Static
Undefined
Undefined
123