Basic Index Spsvovfl - Nortel DMS-100 Series Application Manual

Switch performance monitoring system
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

7-32
7-32
SPMS PROVRES index descriptions

Basic index SPSVOVFL

Section
SRVCTRES
Description
Special service overflow
Definition
The number of failed attempts to connect to DTMF senders, MFC R2
inter-register signaling circuits, and service observing circuits because no
idle circuit was available.
DMS-100G Switch does not contribute to or provide an equivalent of OM
group SVCT.
Measurement list
SPSVOVFL uses measurement SVCT SVCQOVFL and SVCQABAN
summed over all circuit types.
Normalizer
SPSVOVFL is normalized per attempt as given by the sum of SVCT
measurements SVCSZRS (with its extension register SVCSZ2),
SVCQOVFL, and SVCQABAN, totalled over all circuit types.
Diagnostics
Identify the overflowing special service circuit group from OM group
SVCT. Check LINE138, TRK138, LINE108, and TRK182 logs.
297-1001-330 Standard 11.04 June 1998
7-32

Advertisement

Table of Contents
loading

Table of Contents