Nortel DMS-100 Series Application Manual page 151

Switch performance monitoring system
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

Section
CONTROL
Description
Message switch unit manual outage
Definition
The unit unavailability of MS nodes as a result of manual action.
Measurement list
MSUMOUT uses the sum of MS measurements MSMBU totalled over both
message switches.
Normalizer
MSUMOUT is normalized per unit per unit time. The number of MS nodes
is always two.
Diagnostics
Verify OM group MS (MSMBU) and ensure that the results in it agree with
manual maintenance activity.
DMS-100 Family Switch Performance Monitoring System Application Guide BASE09 and up
6-37
SPMS MTCEPERF index descriptions
for SuperNode CONTROL components
Basic index MSUMOUT
6-37
6-37