6-78
6-78
SPMS MTCEPERF index descriptions
Basic index XPMFLT
Section
CONTROL
Description
XMS-based peripheral module faults
Definition
The unit failure rate of the peripheral module types listed in XPMPERF.
DMS-100G Switch does not contribute to or provide an equivalent of OM
group PMTYP, measurement PMTFLT
Measurement list
XPMFLT uses measurement PMTYP PMTFLT summed over all PM types
covered in XPMPERF.
Normalizer
XPMFLT is normalized per working unit per unit time, where the working
units are of the PM types covered by the respective indices. Note that there
are two units per module of the PM types covered by XPMFLT.
Diagnostics
In OM group PM, locate those XPMs with high fault measurements. For
further information analyze PM subsystem logs. Diagnose fault conditions
at the PM level of the MAP. Refer to the PMTOTFLT index description for
further diagnostic information.
297-1001-330 Standard 11.04 June 1998
6-78