Basic Index C7Trkcfl - Nortel DMS-100 Series Application Manual

Switch performance monitoring system
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

6-212
6-212
SPMS MTCEPERF index descriptions

Basic index C7TRKCFL

Section
TERMNALS
Description
CCS7 ISUP trunk connection failure
Definition
C7TRKCFL monitors the failure to make ISDN user part (ISUP) end-to-end
connections due to one or more of the following reasons:
Measurement list
C7TRKCFL is the sum of ISUPCONN measurements ISCONUCE,
ISCONUCC, ISCONUCF, ISCONCOT, and ISCONUCA.
Normalizer
C7TRKCFL is normalized by the number of initial address messages (IAM)
sent. The measurements ISMSGOUT and ISMSGOT2 of OM group
ISUPUSAG are indexed by key IAM.
Diagnostics
Verify OM group ISUPUSAG, registers ISCONUCE, ISCONUCC,
ISCONUCA, ISCONUCF, and ISCONCOT. See logs C7UP106 and
C7UP105 for the reason of an incomplete address, and log C7UP107.
297-1001-330 Standard 11.04 June 1998
switching equipment connection
circuit availability
incomplete address
temporary failures
continuity check request (CCR) test failures
6-212

Advertisement

Table of Contents
loading

Table of Contents