SPMS MTCEPERF index descriptions

Basic Index DAMSGFLT

Section
TERMNALS
Description
Directory assistance message fault
Definition
Monitors the performance of the attempts to send messages from the DMS
central control (CC) to the directory assistance system (DAS).
Measurement list
DAMSGFLT is calculated from the accumulation of the DALINK
measurement MSGSNDFL.
Normalizer
DAMSGFLT is normalized by the number of attempts made to send a
message from the DMS central control (CC) to the directory assistance
system (DAS) during a directory assistance call. This value is given by the
measurement MSGSENT in DALINK.
Diagnostics
Check OM group DALINK register MSGSNDFL.