Basic Index Meterpf - Nortel DMS-100 Series Application Manual

Switch performance monitoring system
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

6-108
6-108
SPMS MTCEPERF index descriptions

Basic index METERPF

Section
BILLPERF
Description
Metering performance
Definition
The summary of the error performance during central control (CC) metering.
Measurement list
METERERR uses the sum of measurements DTCALLP, DTXPM, DTFEAT,
TIMEST0, DURERR, COUNTERR, MTRBKERR, MTRAUDER,
RECYCFND, RECYCCLR, THQOVFL, THQERR, and TODXPMFL of
OM group MTRPERF.
Normalizer
METERPF is normalized per metered calls obtained from OM group
MTRUSG registers LNXPMM1, LNXPMM2, TKXPMM1, TKXPMM2,
LNCCM1, LNCCM2, TKCCM1 and TKCCM2.
Diagnostics
Check OM group MTRPERF and logs MTR100 through MTR142.
297-1001-330 Standard 11.04 June 1998
6-108

Advertisement

Table of Contents
loading

Table of Contents