Basic Index Ioclksuo - Nortel DMS-100 Series Application Manual

Switch performance monitoring system
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

Section
LINKPERF
Description
Input/output controller (IOC) link system unit outage
Definition
The unavailability of links between the IOCs and I/O devices or device
controllers.
Measurement list
IOCLKSUO uses the sum of IOC measurement IOCLKSBU.
Normalizer
IOCLKSUO is normalized per working P-side IOC link per unit time.
Diagnostics
Verify OM group IOC (IOCLKSBU). Further information is available from
IOD subsystem logs IOD103, IOD104, IOD108, IOD109, IOD112, and
IOD113. Diagnose IOC P-side port problems at the IOC and CARD levels
of the MAP.
DMS-100 Family Switch Performance Monitoring System Application Guide BASE09 and up
6-117
SPMS MTCEPERF index descriptions

Basic index IOCLKSUO

6-117
6-117