Basic Index Pmswerr - Nortel DMS-100 Series Application Manual

Switch performance monitoring system
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

Section
CONTROL
Description
Peripheral module software error
Definition
The per-call rate at which PMs generate messages to the CC indicating
software or firmware error conditions.
Measurement list
PMSWERR uses measurement LOGS PMSWERCT.
Normalizer
PMSWERR is normalized per total call attempt on the switch.
Diagnostics
From the OM group PM and PM log reports PM122, PM124, PM125,
PM126, and PM180, identify the PMs responsible for poor values. If the
error condition cannot be corrected, report the condition promptly to Nortel
Technical Support, making sure to keep copies of the applicable log
messages.
DMS-100 Family Switch Performance Monitoring System Application Guide BASE09 and up
6-93
SPMS MTCEPERF index descriptions

Basic index PMSWERR

6-93