Basic Index Pmtousou - Nortel DMS-100 Series Application Manual

Switch performance monitoring system
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

6-52
6-52
SPMS MTCEPERF index descriptions

Basic index PMTOUSOU

Section
CONTROL
Description
Peripheral module total units system outage
Definition
The average unit unavailability of peripherals of the switch, as a result of
system actions.
DMS-100G Switch does not contribute to or provide an equivalent of OM
group PMTYP, measurement PMTUSBU
Measurement list
PMTOUSOU uses PMTYP measurement PMTUSBU, totalled over all
peripheral types covered by the TMPERF, DCMPERF, LMPERF,
XPMPERF, and LCMPERF indices.
Normalizer
PMTOUSOU is normalized per working peripheral unit per unit time.
Diagnostics
Locate in OM group PMTYP (PMTUSBU) and in OM group PM
(PMUSBU) those PMs with high outage measurements. For further
information, analyze PM subsystem logs PM102, PM105, PM128, PM152,
PM182, PM183, PM190, PM191, PM192, CCS234, CCS218, and CCS233.
297-1001-330 Standard 11.04 June 1998
6-52