6-12
6-12
SPMS MTCEPERF index descriptions

Basic index CMCUSOUT

Section
CONTROL
Description
Central message controller unit system outage
Definition
The unavailability of CMCs and their associated system clocks as a result of
system action.
Measurement list
CMCUSOUT uses the sum of CMC measurement CMCSBU totalled over
both CMCs.
Normalizer
CMCUSOUT is normalized per unit per unit time. The number of CMC
units is always 2.
Diagnostics
Verify OM group CMC (CMCSBU). Diagnose error and fault conditions
promptly at the CMC or SYNCLK levels of the MAP. Look for detailed
information in the CMC subsystem logs CMC101 and CMC102.
297-1001-330 Standard 11.04 June 1998