6-202
6-202
SPMS MTCEPERF index descriptions
Basic index SLMMOUT
Section
TERMNALS
Description
System load module (SLM) manual outage
Definition
The unavailability of the primary SLM, caused by manual action.
Measurement list
SLMMOUT uses measurement SLMMBSU of OM group SLM.
Normalizer
SLMMOUT is normalized per working SLM unit per unit time.
Diagnostics
Check OM group SLM, register SLMMBSU. Check logs SLM401,
SLM402, and SLM403 for more details.
297-1001-330 Standard 11.04 June 1998
6-202