9. Click Save to save the new profile.
10. Click OK to close the GC Directory window.
11. Select Chromatograph → Connect... to connect to the GC or click
12. Locate the new GC profile and click the Ethernet button that is associated with it.
13. Enter a User Name and User Pin and click OK.
4.4.13
Wiring the discrete digital inputs and outputs
The backplane has five discrete outputs and five discrete inputs. Refer to the
MON2020 Software for Gas Chromatographs Reference Manual
the digital outputs.
Related information
Wire a ROC800 digital output (DO) module
Wire the discrete digital inputs
WARNING
Electric shock
Failure to observe this precaution may cause serious personal injury or death.
The equipment operates using mains voltage that is dangerous to life. Make sure that the
circuit breakers are set to OFF and tagged off before removing the top cover or opening
the front cover.
WARNING
Explosion
Failure to de-energize the analyzer may cause an explosion and severely injure personnel.
Before opening the analyzer, disconnect all electrical power and ensure that the area is
free of explosive gases.
Keep cover tight while circuits are live.
Use cables or wires suitable for the marked "T" ratings.
Cover joints must be cleaned before replacing the cover.
Conduit runs to the enclosure must have sealing fitting adjacent to enclosure.
To connect digital signal input lines to the gas chromatograph (GC):
Procedure
1. Disconnect power to the analyzer and allow the components to cool for at least five
2. Open the electronics enclosure door and access the back plane.