Manuals and User Guides for Emerson NetSure 721NPBB. We have
2
Emerson NetSure 721NPBB manuals available for free PDF download: System Application Manual, User Instructions
Emerson NetSure 721NPBB System Application Manual (125 pages)
48V DC @ up to 4000 Amperes Power System
Brand:
Emerson
| Category:
Power Supply
| Size: 9.16 MB
Table of Contents
System Overview
1
Distribution Row
4
Table of Contents
7
List Descriptions (582127000)
11
List Numbers (582127000)
11
List 1: Main Bay Common Equipment (Power and Distribution)
11
Located In-Line with Main Bay
12
List 3: 2
14
Located In-Line with Main Bay
14
List 4: Distribution Only Bay Distribution Cabinet Bottom Rear Cover
15
List 5
15
Located Remote from Main Bay
15
List 6: 2
17
Located Remote from Main Bay
17
List 21: One-Row Distribution Cabinet
18
List 22: Two-Row Distribution Cabinet
19
List 23: Three-Row Distribution Cabinet
19
List 24: Four-Row Distribution Cabinet
20
List 29: Top Shield for Distribution Cabinet
20
List 30: Module Mounting Shelf Interface Components (for Spec. No. 58870500021, 58870500022, 58870500031, 58870500032)
20
List 31: Module Mounting Shelf Field Expansion Kit (for Spec. No. 58870500022, 58870500031, 58870500032)
21
List 32: Module Mounting Shelf Interface Components (for Spec. No. 588705300)
22
List 33: Module Mounting Shelf Field Expansion Kit (for Spec. No. 588705300)
22
List 34: Module Mounting Shelf Interface Components (for Spec. No. 58870500040, 58870500041, 58870500042)
23
List 35: Module Mounting Shelf Field Expansion Kit (for Spec. No. 58870500041, 58870500042)
23
List 40: Front Access AC Input Termination Assembly (1 AC Feed Per 1 Rectifier, Single Phase, 1- 5 Shelves)
24
List 41: Front Access AC Input Termination Assembly (1 AC Feed Per 2 Rectifiers, Single Phase, 2 or 4 Shelves)
24
List 42: Front Access AC Input Termination Assembly (1 AC Feed Per 3 Rectifiers, 3-Phase, 1-5 Shelves)
24
List 45: Front Access DC Input Termination Assembly (1 DC Feed Per 1 Converter, 1-5 Shelves)
25
List 46: Front Access DC Input Termination Assembly (1 DC Feed Per 2 Converters, 2 or 4 Shelves)
25
List 47: Front Access DC Input Termination Assembly (1 DC Feed Per 3 Converters, 1-5 Shelves)
25
List 60: Converter Interface Components (for Spec. No. 588705300)
26
List 90: Optional Battery Shunt, 800A
26
Issue AF, February
26
List 91: Optional Battery Shunt, 2000A
27
List 92: Optional Battery Shunt, 2500A
27
Issue AF, February
27
List 93: Optional Battery Tray, Pre-Cabled
28
Spec. No. 582127000 (Model
28
Single Voltage Distribution Panels
29
List AA: -48V Distribution Panel (with Return Busbar) and List AB: -48V Distribution Panel (Without Return Busbar), (24) Bullet/Tps/Tls Circuit Breaker/Fuse Positions
29
Sag582127000
30
List AC: -48V Distribution Panel (with Return Busbar) and List AD: -48V Distribution Panel (Without Return Busbar), (4) GJ/218 Circuit Breaker Positions
30
List AE: -48V Distribution Panel, (2) TPH Fuse Positions (Without Shunts) (Without Return Busbar)
31
List AF: -48V Distribution Panel, (2) TPH Fuse Positions (with Shunts) (Without Return Busbar)
32
List AG: -48V Distribution Panel, (4) TPH Fuse Positions (Without Shunts) (Without Return Busbar)
33
List AH: -48V Distribution Panel, (4) TPH Fuse Positions (with Shunts) (Without Return Busbar)
34
List AJ: -48V Distribution Panel, (4) TPL-B Fuse Positions (Without Shunts) (Without Return Busbar)
35
List AK: -48V Distribution Panel, (4) TPL-B Fuse Positions (with Shunts) (Without Return Busbar)
36
Dual Voltage Distribution Panels
37
Busbar)
37
Busbar)
38
Busbar)
39
Busbar)
40
Battery Disconnect Distribution Panels
41
List BA: Battery Disconnect Distribution Panel (with Return Busbar) and List BB: Battery Disconnect Distribution Panel (Without Return Busbar), (24) Bullet/Tps/Tls Circuit Breaker/Fuse Battery Disconnect Positions
41
List BC: Battery Disconnect Distribution Panel (with Return Busbar) and List BD: Battery Disconnect Distribution Panel (Without Return Busbar), (4) GJ/218 Circuit Breaker Battery Disconnect Positions
42
Shunts) (Without Return Busbar)
43
Shunts) (Without Return Busbar)
44
List BG: Battery Disconnect Distribution Panel, (4) TPH Fuse Battery Disconnect Positions (Without Shunts) (Without Return Busbar)
45
Shunts) (Without Return Busbar)
46
Return Bar Panel
47
List GA: Return Bar Panel
47
Battery Disconnect Contactors
48
List CA: 600A Battery Disconnect Contactor
48
List CB: 1200A Battery Disconnect Contactor
48
List CC: 2000A Battery Disconnect Contactor
48
Low Voltage Disconnect Options
49
List LB: Low Voltage Battery Disconnect (LVBD)
49
List LL: Low Voltage Load Disconnect (LVLD)
49
Manual Battery Disconnect Option
49
List MB: Manual Battery Disconnect
49
Accessory Descriptions
50
ACU+ (Advanced Control Unit Plus) Controller, P/N 1M820DNA
50
Optional ACU+ EIB (Extended Interface Board), P/N 548120
50
Optional SM-DU+ Shunt Monitoring, P/N 548078
51
Optional Temperature Probes
51
Optional SM-Temp Temperature Concentrator, P/N 547490
52
Rectifiers
53
Rectifier Module, P/N 1R483500E
53
Rectifier Module, P/N 1R483200E
53
Rectifier Module, P/N 1R483200
53
Rectifier Module, P/N 1R482000E3
53
Converters
54
DC-DC Converter Module, P/N 1C400483500E
54
DC-DC Converter Module, P/N 1C48241500
54
Module Mounting Position Blank Cover Panel, P/N 21140440
54
Converter Interface Components (for Spec. No. 588705300)
55
Relay Racks and Shipping Brackets
56
Transition Plates to Mount Relay Rack on Top of GNB Absolyte IIP Batteries
57
Batteries
58
Optional Battery Tray Battery Disconnect Circuit Breaker and Housing Kits
59
Optional Battery Tray Front Battery Cover Kits
60
Crimp Lugs
61
Standard Crimp Lug Tables
61
Special Application Crimp Lug / Strap Combination Table
62
Lug Adapters
63
Busbar for 125A, 150A, and 200A Bullet Nose Type Circuit Breaker, P/N 520989
63
Busbar for 125A, 150A, and 200A Bullet Nose Type Circuit Breaker, P/N 522786
63
Lug Adapter Busbar Kit for 125A, 150A, and 200A Bullet Nose Type Circuit Breaker, P/N 534449
63
Busbar for 250A Bullet Nose Type Circuit Breaker, P/N 514717
63
Lug Adapter Busbar Kit for 250A Bullet Nose Type Circuit Breaker, P/N 514714
64
Lug Hardware Kits
64
1/4-20 Hardware Kit, P/N 541084
64
3/8-16 Hardware Kit, P/N 548184
64
3/8-16 Hardware Kit, P/N 548185
64
Battery Busbar Extension Kit (P/N 554541)
65
Battery Landing Busbar Kit (P/N 553584)
65
Battery Landing Busbar Kit (P/N 555478)
65
Distribution Devices
66
Bullet Nose Type Circuit Breakers and Bullet Nose Type Fuseholders E/W TPS/TLS Fuses
66
Positions
68
Optional Bullet Nose Type 6-Position GMT Distribution Fuse Block, P/N 550224, (6) GMT Fuse Positions
71
GMT Type Load Distribution Fuses
72
GJ/218 Type Circuit Breakers
73
TPH Type Fuses
74
TPL-B Type Fuses
75
Replacement Alarm, Reference, and Control Fuses
76
Replacement Assemblies
76
Replacement Bay-To-Bay Interconnect Cable
76
Wiring Illustrations and Notes
77
Relay Rack Frame Grounding Requirements
77
AC Input
78
4-Row Cabinet Shown
84
4-Row Cabinet Shown
85
4-Row Cabinet Shown
86
400V DC Input
87
4-Row Cabinet Shown
90
4-Row Cabinet Shown
91
4-Row Cabinet Shown
92
Field Installed Module Mounting Shelves
93
External Alarm, Reference, Monitoring
93
List 21 (1-Row
99
Load Distribution
101
Battery Input
103
Distribution Cabinet
104
Distribution Cabinet
106
Distribution Cabinet
107
Distribution Cabinet
108
Wire Size and Lug Selection Tables for Load and Battery Connections to TPS/TLS Fuses and Bullet Nose Type Circuit Breakers
109
Wire Size and Lug Selection Tables for Load and Battery Connections to TPH Fuses, TPL-B Fuses, and GJ/218 Type Circuit Breakers or Battery Branch Circuits
111
Input Ratings
113
Sag582127000
113
Environmental Ratings
113
Specifications
113
Output Ratings
113
Compliance Information
114
IB2 and EIB (ACU+ Interface Board) Ratings
114
Physical Size Information
115
Overall Dimensions
115
List 21 (One-Row Distribution Cabinet)
116
List 22 (Two-Row Distribution Cabinet)
117
List 23 (Three-Row Distribution Cabinet)
118
List 24 (Four-Row Distribution Cabinet)
119
List 93 (Battery Tray)
120
Weights
121
Related Documentation
124
Battery Manufacturer Information
124
Revision Record
125
Advertisement
Emerson NetSure 721NPBB User Instructions (60 pages)
-48V DC Power System
Brand:
Emerson
| Category:
Power Supply
| Size: 6.67 MB
Table of Contents
Table of Contents
3
Admonishments Used in this Document
4
Important Safety Instructions
5
General Safety
5
Voltages
5
Battery
5
Personal Protective Equipment (PPE)
6
Hazardous Voltage
6
Handling Equipment Containing Static Sensitive Components
6
Static Warning
7
System Overview
9
Customer Documentation Package
9
System Description
9
Operating Procedures
10
Controller, Rectifiers, and Converters
10
ESTOP Function
10
ACU+ Battery Charge Current Limit Feature
10
Local Controls and Indicators
10
Maintenance
17
System Maintenance Procedures
17
Adding a Rectifier or Converter Module to an Existing Module Mounting Shelf Spec. No. 588705000
17
Adding a Rectifier or Converter Module to an Existing Module Mounting Shelf Spec. No. 588705300
17
Installing a Field Expansion Module Mounting Shelf Spec. No. 588705000
19
Installing a Field Expansion Module Mounting Shelf Spec. No. 588705300
23
Changing the ACU+ LVD Control Level for a Contactor
26
Adding a Supplemental Bay in the Field
26
Troubleshooting and Repair
26
Contact Information
26
Controller, Rectifiers, and Converters
26
ACU+ Controller Configuration
26
System Troubleshooting Information
26
Replacement Information
28
Replacement Procedures
28
Netperform™ Optimization Services
59
Advertisement
Related Products
Emerson NetSure 701 A51
Emerson NetSure 710NPBA
Emerson Rosemount 700XA
Emerson SmartPower 701PBK
Emerson SmartPower 701PGN
Emerson SmartPower 701P
Emerson NetSure 211 C23
Emerson NetSure 211 C45
Emerson netsure 9500
Emerson NetSure 5100