Removing the Pensando DSP DSC-25 2p SFP28 card with the iLO Sideband ALOM Module

Removing the Pensando DSP DSC-25 2p SFP28 card with the iLO Sideband ALOM Module
Pensando Distributed Services Platform for HPE iLO Sideband Management ALOM Module requires that the accompanying Smart I/O
card (such as the Pensando DSP DSC-25 2p SFP28 card) be installed on slot 1 of the primary PCIe riser cage.
Procedure
Procedure
1. Observe the following alerts:
WARNING: To reduce the risk of personal injury from hot surfaces, allow the drives and the
WARNING:
internal system components to cool before touching them.
CAUTION:
CAUTION:
Electrostatic discharge (ESD) can damage electronic components. Be sure that you are properly grounded (earthed)
before beginning any installation procedure.
CAUTION:
CAUTION:
To prevent improper cooling and thermal damage, do not operate the server unless all PCI slots have either an
expansion slot cover or an expansion board installed.
2. Power down the server.
3. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
4. Extend the server from the rack .
5. Remove the server from the rack .
6. Remove the access panel .
7. Disconnect the auxiliary cable from the DSC-25 card before removing the PCIe riser cage.
NOTE:
NOTE:
The PCIe riser cage is not shown in this illustration for clarity purposes.
8. Remove the primary PCIe riser cage.
Removing the Pensando DSP DSC-25 2p SFP28 card with the iLO Sideband ALOM Module
123